Omega-vehicle-security LDN-PS Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Omega-vehicle-security LDN-PS. Omega Vehicle Security LDN-PS User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - User’s Guide

omega.com e-mail: [email protected] latest product manuals:omegamanual.infoUser’s GuideLDN-PSShop online atsolartron6951

Page 2 - OMEGAnet

4.0: PSIM Schematic and Pin-outThe 5V power supply line from the network is isolated at the PSIM.All modules before the PSIM are powered from the netw

Page 3

4.0: PSIM Schematic and Pin-out (continued)The PSIM will only supply power to the Orbit Modules that follow the PSIM. Some typical configurations are

Page 4 - 1.0: Introduction

5.1 Power SupplyThe mounting plate must notbe removed. The mountingplate is isolated and does notneed to be at earth potential.The power supply may be

Page 5 - 2.0: Safety Information

PSIM-AC PSIM-DC PSIM-5V5.0: Dimensions and Mechanical Installation(continued)5.2 PSIMT-CON is permanently attached, module does notseparate.For more i

Page 6

PSIM-AC PSIM-DC PSIM-5V6.0: SpecificationInputVoltage 85 to 264 Vac @ 47 Hz to 440 Hz.Current 0.8 AConnection via IEC320 connectorIsolation 2500 Vac i

Page 7 - 3.0: General Information

6.0: Specification (continued)PSIM-AC PSIM-DC PSIM-5VInputLine Voltage 10 to 30 Vdc.Current 1.1 A @ 12 Vdc; 0.5 A @ 24 Vdc (nominal).Connection see no

Page 8 - Power Supply

6.0: Specification (continued)PSIM-AC PSIM-DC PSIM-5VLine Voltage see note 1 5.1 Vdc Nominal as supplied by user 5.25 Vdc MAXInput Current 1.8 A MAXCo

Page 9

6.0: Specification (continued)PSIM-AC PSIM-DC PSIM-5VEnvironmentalOperational temperature 0 to 60 °CStorage temperature -20 to 60 °CHumidity 5% to 95%

Page 10 - PSIM Schematic and Pin-out

Orbit Network Power Supply Requirements All Orbit Modules are designed to work from a supplyvoltage of 4.75V to 5.25 Vdc. When power is applied toa

Page 11 - M-3340/1206

7.0: Applications (continued)Voltage Drop EstimationThe following information is for guidance only when planning an installation. Voltage measurements

Page 12

Servicing North America:USA: One Omega Drive, Box 4047ISO 9001 CertifiedStamford CT 06907-0047Tel: (203) 359-1660 FAX: (203) 359-7700e-mail:

Page 13 - (continued)

PSIM-AC PSIM-DC PSIM-5V7.0: Applications (continued)Application 1: Basic Small Network Connection.• Power supplied to network from PC via network card

Page 14 - 6.0: Specification

PSIM-AC PSIM-DC PSIM-5V7.0: Applications (continued)Application 2: Large network with modules close to computer and at a distance.• Power supplied fro

Page 15 - Specification (continued)

PSIM-AC PSIM-DC PSIM-5V7.0: Applications (continued)Volt drop V1is calculated in a similar way to the previous example except there is only a single c

Page 16

PSIM-AC PSIM-DC PSIM-5V7.0: Applications (continued)Application 3: Large Network using PSIM-5V and RS232IM for network control.LDN-PS22M-3340/1206

Page 17

PSIM-AC PSIM-DC PSIM-5VThe PSIM-5V is powering the whole Orbit Network. PSIM-5V volt drop is calculated using 12 as the total number ofOrbit modules;

Page 18 - 7.0: Applications

PSIM-AC PSIM-DC PSIM-5V7.0: Applications (continued)Application 4: Modules located a long distance from computer.• Also for a computer that is not sui

Page 19 - 7.0: Applications (continued)

7.0: Applications (continued)PSIM-AC PSIM-DC PSIM-5VApplication 5: Use with RS232 Interface Module (RS232IM).• Communication is via a RS232IM.• Power

Page 20

M-3340/1206WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials andworkmanship for a period of 13 months f

Page 21

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop online at www.omega.comM-3340/1206TEMPERATUREThermocouple

Page 22

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 23

PSIM-AC PSIM-DC PSIM-5VIntroductionThe Power Supply Interface Module (PSIM) is part of theOrbit Measurement System. The PSIM provides localpower to th

Page 24

This equipment is designed as safety Class 1 apparatusto comply with EN61010-1.Service SafetyThis equipment has been designed and tested to meetthe re

Page 25

WARNING: Danger arising from loss ofground. During a fault condition and upon lossof protective ground (earth), all accessibleconducting parts - inclu

Page 26 - Applications (continued)

3.0: General InformationPSIM-AC PSIM-DC PSIM-5VLDN-PS6M-3340/12066951Power SupplyOUTPUTPSIM Variants6951Power SupplyOUTPUT6951Power SupplyOUTPUTPSIM-A

Page 27 - RETURN REQUESTS/INQUIRIES

LDN-PS7M-3340/12063.0: General Information (continued)PSIM-AC PSIM-DC PSIM-5VPSIM General LayoutPSIM9111731 7 3 A 1 2 3 R 0 16951Power SupplyOUTPUT695

Page 28 - OMEGA…Of Course!

PSIM used in a small network configuration3.0: General Information (continued)PSIM-AC PSIM-DC PSIM-5VLDN-PS8M-3340/1206