kD
Voltage Thresholds: Low 0 to 0.4 V dc
High 2.0 to 28 V dc
Maximum High 28 V dc
PROGRAM ENABLE INPUT (Terminal 5)
Operation: Level sensitive (maintained)
COUNT ACCURACY
Absolute when operated within specifications.
DPCl O-CC
Inputs A & B are designed for contact closures to dc common.
Speed: 0 to 20 Hz
Minimum Low Time: 10 milliseconds
Minimum High Time: 40 milliseconds
Input Impedance: 101
2KR
above 5 V dc
Voltage Thresholds: Low 0 to 1.2 V dc, High 2.0 to 28 V
dc, Maximum High 28 V dc
kHz
Minimum Low Time: 80 microseconds
Minimum High Time: 20 microseconds
(These times are with a O.OV to 5.0 V swing.)
Input Impedance:
DPCl&CS
Inputs A& B require a voltage source, such as a current sourcing
sensor or a current sinking sensor used with the provided pull up
resistors.
Speed: 0 to 10
2&3)
)
Decimal Point: 5 positions, programmable
DC COMMON (Terminal 1)
EXTERNAL RESET INPUT (Terminal 4)
Resets totalizer when connected to dc common.
Minimum Low Time: 0.25 to 1 .O sec. (maintained)
The required pulse width varies with count speed, scale
factor and number of digits displayed.
Voltage Thresholds: Low 0 to 0.4 V dc
High 2.0 to 28 V dc
(TERMINALS
-
100.0000
(0.0000 scales by 100
TOTALIZER
Type: Up/Down Counting
Digits: 8 digits positive/minus sign and 7 digits negative
Scaler: 0.0001
.43 high
Front Panel Rating: NEMA-4X when mounted
with gasket provided
Case Material: Cycolac X-17
#
Operating Humidity: 90% Non-condensing
Weight: 2.2 oz. net
Display Size:
55°C
Storage Temperature: -20 to 70°C
-
0”
DPClO-BAT
PHYSICAL
Operation Temperature:
3V,
lithium
Life expectancy: 5 years +
Replacement Part:
I
1.299
(33mm)
POWER
COUNT INPUT A (SUBTRACT); COUNT INPUT B (ADD)
Internal battery:
Recommended
Panel Cutout
I
-w
(68mm)
f---
2.677
-H
7mm)
(74.93mm)
b-
2.95 ”
663/0693
DPCI O-CC Add/Subtract Totalizer (Contact Inputs)
Ml
O-CS
Add/Subtract Totalizer (Solid State Inputs)DPCI
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - 663/0693

kDVoltage Thresholds: Low 0 to 0.4 V dcHigh 2.0 to 28 V dcMaximum High 28 V dcPROGRAM ENABLE INPUT (Terminal 5)Operation: Level sensitive (maintained)

Page 2 - ‘~‘lnstall mounting clip

+0.4 V dc or less. Counts are entered on the negative-goingedge of the pulse.Page 2+3 V dc. The sensor must be capable of sinkingcurrent from the inpu

Page 3

m key. Repeat this process until all digits are setcorrectly.them key to move the flashing digit one placeto the left. Change this digit to the desire

Page 4 - Coil Suppression:

,Page 4(DPCIO-CS)Count InputCurrent Sink Input (DPCIO-CC)4ResetConnect through ContactClosure to Ground5ProgramConnect to Ground to EnterEnableProgram

Page 5 - ‘~ ,\sp ”: ‘rr;

Nothinginthismenualmaybereproducedinanymanner,eitherwhollyorinpa~forenypurposewhatsoever without written permission from OMEGA ENGINEERING, INC.Printe

Page 6

@ Laboratory HeatersENGINEERING INC.One Omega Drive, P.O. Box 4047Stamford, CT 06907Tel: (203) 359-1660Telex: 996404 Cable OMEGAFax: (203) 359-7700m F

Commentaires sur ces manuels

Pas de commentaire