Omega-vehicle-security OMEGAFLEX FPU500 Manuel d'utilisateur Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
Troubleshooting Guide
7
7-3
Problem Solution
Motor will not turn 1. Make sure the tubing is loaded
properly. The tubing should be
centered in the middle of the rollers.
Reload if necessary.
2. Check to see if the motor is turned
on.
3. Check motor fuse.
Motor will not turn – 1. Make sure the tubing is loaded
overcurrent condition properly. The tubing should be
centered in the middle of the rollers.
2. Make sure the tubing wall thickness
is correct (refer to Table 9-1).
3. The tubing durometer may be too
high for the pump (refer to Chapter
9).
4. The tubing may be caught on the
bottom roller. Reposition the roller
slightly and load the tubing again.
The pump will not stay on the 1. The pump is not properly mounted
motor to the motor. Refer to Section 3.
2. The mounting screws are loose.
Tighten the screws, if necessary.
Vue de la page 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 51 52

Commentaires sur ces manuels

Pas de commentaire