11
WIRING(continued) StepSix
Wiring the Relay Output:The LVP‐51‐R requires 12‐36 VDC power to operate the sensor and switch the
relay.AllillustrationsbelowidentifyaDryswitchstateasthenormalpositionoftherelay.
SwitchingaNormallyOpenDCLoad:
The Red wire connects to Positive (+) of the power
supply and the Black wire connects to Negative (‐).
The LOAD can be attached to either the Green or
Whitewires.Completethecircuitbyconnectingthe
Green to (+) VDC power or White to (‐) VDC power
(seeillustrationbelow).
SwitchingaNormallyClosedDCLoad:
The Black wire connects to Positive (+) ofthe power
supplyandtheRedwireconnectstoNegative(‐).The
LOAD can be attached to either the Green or White
wires.CompletethecircuitbyconnectingtheGreen
to (+) VDC power or White to (‐) VDC power (see
illustrationbelow).
SensorPower
[RED&BLKwires]/36VDCMax.
5±1mADry/20±1mAWet
RelayRating
[GRN&WHTwires]/60VA
SwitchingaNormallyOpenACLoad:
The Red wire connects to Positive (+) of the DC
power supply and the Black wire connects to
Negative (‐).The LOAD can be attached to the
GreenwireandtheHotoftheVACpower.Connect
the White to the Neutral of the VAC power (see
illustrationbelow).
SwitchingaNormallyClosedACLoad:
TheBlackwireconnectstoPositive(+)oftheDCpower
supplyandtheRedwireconnectstoNegative(‐).The
LOADcanbeattachedtotheGreenwireandtheHotof
the VAC power.Connectthe Whiteto the Neutral of
theVACpower(seeillustrationbelow).
SensorPower
[RED&BLKwires]/36VDCMax.
5±1mADry/20±1mAWet
RelayRating
[GRN&WHTwires]/60VA