WIRING(continued) StepSix
Wiring the Relay Output:The LVP51R requires 12‐36 VDC power to operate the sensor and switch the
relay.AllillustrationsbelowidentifyaDryswitchstateasthenormalpositionoftherelay.
SwitchingaNormallyOpenDCLoad:
The Red wire connects to Positive (+) of the power
supply and the Black wire connects to Negative ().
The LOAD can be attached to either the Green or
Whitewires.Completethecircuitbyconnectingthe
Green to (+) VDC power or White to () VDC power
(seeillustrationbelow).
SwitchingaNormallyClosedDCLoad:
The Black wire connects to Positive (+) ofthe power
supplyandtheRedwireconnectstoNegative().The
LOAD can be attached to either the Green or White
wires.CompletethecircuitbyconnectingtheGreen
to (+) VDC power or White to () VDC power (see
illustrationbelow).

SensorPower
[RED&BLKwires]/36VDCMax.
5±1mADry/20±1mAWet
RelayRating
[GRN&WHTwires]/60VA
SwitchingaNormallyOpenACLoad:
The Red wire connects to Positive (+) of the DC
power supply and the Black wire connects to
Negative ().The LOAD can be attached to the
GreenwireandtheHotoftheVACpower.Connect
the White to the Neutral of the VAC power (see
illustrationbelow).
SwitchingaNormallyClosedACLoad:
TheBlackwireconnectstoPositive(+)oftheDCpower
supplyandtheRedwireconnectstoNegative().The
LOADcanbeattachedtotheGreenwireandtheHotof
the VAC power.Connectthe Whiteto the Neutral of
theVACpower(seeillustrationbelow).
SensorPower
[RED&BLKwires]/36VDCMax.
5±1mADry/20±1mAWet
RelayRating
[GRN&WHTwires]/60VA
