12
WIRING(continued) StepSix
Wiring as a P‐Channel or N‐Channel output:The LVP‐51‐R can besubstituted for eitheraP‐Channel(PNP,
sourcing)outputoranN‐Channel(NPN,sinking)output.
NormallyOpenDCLoadasaP‐ChannelOutput:
The Red wire connects to Positive (+) of the power
supply and the Black wire connects to Negative (‐).
The Greenwire is jumped to the Red wire while the
White wire is connected to the LOAD.Jumper the
LOADtotheNegative(‐)tocompletethecircuit.
NormallyClosedDCLoadasaP‐ChannelOutput:
The Black wire connects to Positive (+) ofthe power
supplyandtheRedwireconnectstoNegative(‐).The
Green wire is jumped to the Black wire while the
White wire is connected to the LOAD.Jumper the
LOADtotheNegative(‐)tocompletethecircuit.
SensorPower
[RED&BLKwires]/36VDCMax.
5±1mADry/20±1mAWet
RelayRating
[GRN&WHTwires]/60VA
NormallyOpenDCLoadasaN‐ChannelOutput:
The Red wire connects to Positive (+) of the power
supply and the Black wire connects to Negative (‐).
TheWhitewireisjumpedtotheBlackwirewhilethe
Green wire is connected to the LOAD.Jumper the
LOADtothePositive(+)tocompletethecircuit.
NormallyClosedDCLoadasaN‐ChannelOutput:
The Black wire connects to Positive (+) ofthe power
supplyandtheRedwireconnectstoNegative(‐).The
WhitewireisjumpedtotheRedwirewhiletheWhite
wireisconnectedtotheLOAD.JumpertheLOADto
thePositive(+)tocompletethecircuit.
SensorPower
[RED&BLKwires]/36VDCMax.
5±1mADry/20±1mAWet
RelayRating
[GRN&WHTwires]/60VA