Omega-vehicle-security OMP-MODL Manuel d'utilisateur Page 232

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 297
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 231
11.. . APPENDIX A: MASTER ICON FILE REFERENCE
USING THE OMP-MODL11-70
CONSTANT FUNCTION ICON
FUNCTION:
The Constant icon represents a fixed User defined value. A typical application for the
Constant is as a threshold for use with the Comparator icon as shown below.
In the above net, when the temperature of the engine oil exceeds 130C, the relay output
will be energized.
INPUTS:
Data/Logic Signal: None.
Update Clock: None
Enable: None
OUTPUTS:
Output Signal: Data type, fixed value of User definition.
ICON CONFIGURATION DIALOG BOX:
CONFIGURATION OPTIONS:
Icon Name:Specify the label for the icon. This name will show directly under the icon
within the Program Net.
Constant: Enter the constant value in this text box.
Output Name: Specify the label for the Output. This name will show directly
under the Output terminal within the Program Net.