5... HYPERCOMM™ COMMUNICATIONS
USING THE OMP-MODL
5-10
Clear Button Icon (logger Clear not PCMCIA Clear)
When the logger is not Enabled, double-clicking on this button
results in a clearing of memory (after confirmation). After double-
clicking, a dialog will appear to confirm the action. Memory Status
can always be confirmed with the Status Query command (below).
The logger memory can be cleared while the logger is Enabled.
However, If the logger is Enabled, only memory containing data that
has been downloaded will be cleared. This allows for logger use in
long duration continuous acquistion and download periods without
missed data.
Unit Name and ID Query
Each logger can be assigned an ID and short Name. The ID and
NAME are retained in logger memory until changed via the
following procedure and are not cleared with power down or Memory
Clear commands. On loggers equipped with ML-DISP module both
entries can be displayed on the LCD under the STATUS menu and
are also available via a logger Status Query from the PC
(following).
To program the logger ID and NAME, move the cursor over the LCD
icon on the logger and double-click. A dialog will open for editing.
OK will reprogram the logger to the new ID and NAME.
Status Query
At any time, the logger can be interrogated for its operational Status.
Drag and drop the Status Icon from the logger to the PC and release
it. The Logger Status dialog (Figure 5... -6) will open detailing
operational information.
Figure 5...
-5: Status
icon
Figure 5... -6: Logger Status report dialog