3... INTERFACE MODULES
USING THE OMP-MODL 3-31
MLIM-2; DIGITAL INTERFACE MODULE OVERVIEW
Overview:
The MLIM-2 Interface Module provides four input channels and four output
channels on a single module. Each of the four input channels can be
individually programmed for any combination of Event input, Count input, or
Frequency input. The four output channels provide current limited nominal
5VDC output. Configuration of the module is done from within HyperNet in
HyperWare.
Module Installation:
Refer to the Installation Section earlier in this chapter for detailed installation
instructions of the Interface Module onto the System Base.
I/O Module Layer Requirements / Limitations:
The MLIM-2 module can be installed in any of the five I/O Module positions
(Figure 3... -4). The module layer address must be set on the module to
correspond to the layer position into which the module is installed.
This address is programmed into the module through the use of the Module
Address Switch bank (Figure 3... -17). The switch bank contains 5 switches.
Note the marking on the circuit board identifying address rows for Module
Layers 2 through 5. Set one switch in the bank ON corresponding to a
ml051
Module 3
Module 2
Module 4
Module 5
Module 6
OFF - ON
Module Address (Layer) Switch bank
Figure 3... -17: MLIM-2 Module Address Switch Bank